Skip to content
Calculators

Size the disk array of your
physical server before you build it

See the net capacity and fault tolerance of an array you build on your own hardware or with software RAID. On an izCloud cloud server you simply choose NVMe SSD disk space in GB.

RAID capacity calculation tool

RAID level

From raw to net space

Raw space (label)
–
Raw space (in the OS)
–
Usable after RAID
–
Net space estimate
–

Per disk:

Fault tolerance (guaranteed)
–
Best case
–
Spare disks
–
Total disks
–
Protection overhead
–
Space efficiency
–

Distribution of raw space

  • Data (net)
  • Parity / mirror
  • Spare
  • Unit gap and filesystem

Layout

  • Data
  • Parity share
  • Mirror
  • Spare

RAID levels in brief

  • RAID 0

    Stripes data across the disks; capacity is the sum of all disks but there is no protection. If one disk fails, all data in the array is lost.

  • RAID 1

    Mirrors data between disks; usable space equals one disk. Data survives as long as one copy stays intact.

  • RAID 5

    Needs at least 3 disks. Distributes parity across all disks; survives one disk failure, and capacity is one disk less than the total.

  • RAID 6

    Needs at least 4 disks. Double parity lets it survive two simultaneous disk failures; capacity is two disks less than the total.

  • RAID 10

    A stripe of mirrored pairs; needs at least 4 disks. Capacity drops to half, and one failed disk per pair is tolerated.

  • RAID 50 and 60

    A stripe of RAID 5 or 6 groups. Used in arrays with many disks; each group carries its own fault tolerance, and if one group is exceeded the whole array is affected.

Who needs a RAID calculation, and how do you choose disk on izCloud?

RAID combines several physical disks so that they work as one volume. If you build your own hardware or set up software RAID on a server, this tool shows the capacity and fault tolerance in advance. On an izCloud cloud server you do not pick a RAID level; you set the disk size in GB.

When do you use the calculator?

We compare physical and cloud servers in cloud server or physical server?.

  • To decide how many disks to buy for your own physical server in your office or a data centre
  • Before you build an array with the operating system's software RAID on a physical server (such as mdadm or ZFS on Linux)
  • When you plan a separate storage server for backups or archives
  • To compare the raw capacity in a hardware quote with the space you will actually get

How do you choose disk on an izCloud cloud server?

On izCloud the server disk is NVMe SSD and is allocated in GB from the disk capacity of your pool. You do not work out disk counts, RAID levels or parity overhead; you choose how much space the server gets.

To set the size, add up your current data, its growth rate and extra space for logs and temporary files. The method is in how to determine server resources. A disk can be grown later but not shrunk, so start with what you need. Growing is done while the server is running.

What else should you plan on your own hardware?

RAID covers disk failures only. On a physical server, spare parts and response time for a failed power supply, motherboard or RAID controller are part of your own plan. To notice a failed disk in time you need to watch alerts from the controller or the operating system and be able to fit a new disk quickly.

On a cloud server the provider maintains the hardware; you look after disk size, backups and monitoring.

Which RAID level for a physical server?

LevelSuitsWatch out for
RAID 1Operating system disk, small serversCapacity equals a single disk
RAID 5Read-heavy files and archivesRebuilds take long on large disks; a second failure during a rebuild loses the data
RAID 6Large arrays with many disksDouble parity slows down writes
RAID 10Databases and virtualisationHalf of the raw capacity is usable
RAID 0Temporary data you can afford to loseOne disk failure loses the whole array

Common mistakes

Whatever the platform, keep a separate backup. For your izCloud servers you take a lasting copy with the Server Backup service; a snapshot is limited to one per server and is deleted automatically after 24 hours.

  • Treating RAID as a backup. RAID keeps running through a disk failure; it does not bring back files that were deleted, corrupted or encrypted by ransomware.
  • Mixing up TB on the disk label with TiB in the operating system. A 3.84 TB disk shows up as about 3.49 TiB.
  • Expecting a hot spare disk to add capacity.
  • Ignoring that disks from the same batch and of the same age can fail one after another.

You can choose the disk and resources of your cloud server in the configurator and see the price at once.

Frequently asked questions

How do raw, usable and net space differ?

Raw space is the sum of the disk labels. Usable space is what remains after parity, mirror and spare disks are subtracted. Net space is the estimated free space you see once a filesystem is formatted and TB is converted to TiB.

Why does a 3.84 TB disk look smaller in the operating system?

Manufacturers count 1 TB as 10^12 bytes, while operating systems usually show TiB of 2^40 bytes. A 3.84 TB disk therefore appears as about 3.49 TiB, and the filesystem overhead comes off that.

Does a hot spare disk increase usable space?

No. Spare disks hold no data, so net space stays the same while total raw space and disk count go up. A spare starts a rebuild automatically when a disk fails but does not raise tolerance for simultaneous failures.

What do multiple groups mean?

With RAID 1, 5 and 6, multiple groups are joined into one pool; RAID 10, 50 and 60 stripe across the groups. The guaranteed tolerance is that of a single group; the "best case" figure applies only when failures spread evenly across groups.

Does RAID replace backups?

No. RAID helps a service keep running through a hardware failure, but it does not bring back data that was deleted by mistake, corrupted or encrypted by ransomware. That needs a separate, regular backup.